Standard requirements for generator set room ventilation system


Today's rapid economic development, people's material needs are getting higher and higher, the demand for diesel generator sets is also increasing, then diesel generator sets on the "housing" conditions are also certain requirements.

1, diesel generator set should be installed in a well-ventilated, clean environment, and close to the main power equipment and distribution room in the engine room. Exhaust facilities should be set up in the engine room. Closed diesel generator set room generally does not require forced ventilation, can be exhausted to the outdoors through the fan with the unit, to promote air convection in the engine room. In the engine room of the open diesel generator set, a fan can be set to force ventilation if necessary. In the place far from the unit, use the fan and large diameter air inlet pipe to bring the outdoor air into the engine room. The outlet of the air inlet pipe should be as low as possible, so that the air introduced can be swept through the cooling part of the generator set. Exhaust fan should be installed in the high position, so that the high temperature updraft timely discharge outside.

2, ventilation and dust control to achieve the optimal combination of engine room must have a sufficient amount of fresh air, otherwise dirty air will make the diesel engine power down. Dust will make the insulation between the engine rotor is destroyed, serious will burn the generator set. Well-ventilated, the moisture-proof performance is bound to be properly reduced. Overconsideration of dustproof will affect the ventilation of the generator room. Seemingly contradictory two aspects, the need for generator room designers to calculate and coordinate according to the actual situation to achieve the optimal combination.

3, room ground foundation to grasp the thickness without a specific foundation, can be installed directly in the horizontal plane and concrete ground with sufficient strength, the general thickness should be greater than 200mm.

4、The space arrangement should be reasonable between the units and the distance from the outline of the units to the wall should meet the needs of handling equipment, in-place operation, maintenance and repair or arrangement of auxiliary equipment.

5、The arrangement of smoke exhaust ducts and intake and exhaust louvers can be installed if necessary, and a forced ventilation system can be used. The inlet and exhaust area of the machine room should be at least 2 times of the heat dissipation area. The smoke exhaust pipe of the unit should be wrapped with heat insulation material, and if allowed, the silencer and most of the smoke exhaust pipe should be installed outside the machine room as far as possible. The effective area of the inlet and exhaust louvers should be at least 70%, with good flow and low airflow resistance, and the inner side of the louvers should be equipped with bird, mouse and pest protection net, but the flow of cooling and exhaust air should not be obstructed; the connection between the exhaust louvers and the cooling water tank of the unit should be made with heat-resistant and oil-proof soft material.

6、Configuration of fire extinguishing devices, safety is guaranteed: dry powder fire extinguishers. Including portable and cart type; dry powder automatic fire extinguishing device. Independently suspended can be, when no one is on duty, a fire can automatically start the fire.

Diesel generator set to strictly follow the diesel generator installation environment requirements, diesel generator set installation environment specifications to install and arrange the engine room, the safety fuse to keep away from the fire.

Related News

Requirements for diesel generator set ventilation

Requirements of diesel generator set ventilation (1) The dampers or louvers play a role in isolating the engine room from the surrounding environment, and their opening and closing operations should be controlled by the operating status of the unit.

Buy diesel silent generator need to pay attention to those issues

The current diesel generator is more important in the silent category, but to buy the right silent generator or need to ask the staff about the fuel at the time of purchase. There are three types of fuels that can supply energy to the generator, namely natural gas, gasoline and diesel. Among them, when diesel fuel is used as fuel, the generator runs with more power. Therefore, if you are buying a generator for use in a large factory or business, it is recommended that you choose a generator that uses diesel as its fuel. There is another reason to choose diesel fueled generators, and that is the relatively low cost of using diesel generators.

What are the tips for using diesel generator set batteries?

What are the tips for using diesel generator set battery? Once a diesel generator set is idle for a long time without use, its battery may run out of power, and may even run out, this time should be charged to the battery. Today YANAN motor editor for you to briefly explain the diesel generator set battery use precautions.

Search

We work hard to provide the top quality products and service to our customers

全部
  • 全部
  • 产品管理
  • 新闻资讯
  • 介绍内容
  • 企业网点
  • 常见问题
  • 企业视频
  • 企业图册